Send SMS
Contact Us

Molten Metal Temperature Measuring System

Molten Metal Pyrometer

Approx. Rs 95,000 / Unit


Our range of molten Metal Temperature Indicator is available with remote display. It is provided for thermocouple continuity. Technical specifications (LMI-2010) Sensor Input K, R, S and B-type thermocouple (user selectable) Range Full positive range of the selected input (0 to 1820°C) Accuracy Within +/-0.1% of the range Resolution 1o+/- 1 count Display 4 digit – 2” seven segment red LED display Measurement Time 2 to 9 seconds (user programmable) Plateau Detection 1 to 99o(user programmable) LED indication 13 front panel LEDs for various functions Visual Alarm Indication Provided for Thermocouple Continuity, Measurement in progress, Measurement Over Retransmission Output 4-20mA proportional to the measured temperature, RL (max) = 400 ohms Relay Output Potential free relay changeover contacts for driving remote audio/visual indicator - LLC-2010. Serial Communication RS485 – 2 wire for remote display and computer interface (Using MODBUS RTU protocol) Supply 180 to 250VAC, 50/60 Hz Enclosure Metallic powder coated (IP 50) Size 365 (w) x 265 (h) x 250 (d) mm. Weight 8.5 Kg (approx) Mounting Wall mounting key holes or Can be placed on a flat platform. (LRU-2010) Signal Input 2 wire RS485 serial output from LMI-2010 will be the input to LRU-2010 Display 4 digit – 4” seven segment red LED display LED indication 2 front panel LEDs for RXD and TXD Supply 180 to 250VAC, 50/60 Hz Enclosure Metallic powder coated (IP 50) Size 440(w) x 290(h) x 170(d)mm. Weight 10.0 Kg (approx) Mounting Wall mounting key holes or can be placed on a flat platform.

Additional Information:

Molten Metal Pyrometer 2inch - LMI-2010

Molten Metal Pyrometer 2inch - LMI-2010
  • Molten Metal Pyrometer 2inch - LMI-2010
  • Molten Metal Pyrometer 2inch - LMI-2010

Approx. Rs 45,000 / Number


System Description:

Molten metal Temperature Indicator (LMI-2010): Libratherm offers improved version of LMI-2010, where user has the choice of selecting two types of measurement from a single instrument.

1) Spot measurement (SM) - using disposable thermocouple tips, where the thermocouple tip is dipped into the molten metal for merely 3 to 5 seconds and then withdrawn. In this short measurement time, the operator is guided through the measurement cycle by audio/visual alarms for thermocouple continuity, measurement in progress and measurement over. Once the measurement is over the final reading is latched onto the display. Any error in measurement due to thermocouple open condition is immediately detected and informed by activating the audio/visual alarm. This is very common practice in the industry.

LMI-2010 is designed to measure and display the molten metal temperature in very short time interval. The indicator is rugged, reliable, field proven and very easy to operate. User can select the desired type of thermocouple and also set other parameters using front panel key board. During measurement, the indicator ignores the slag temperature and the Average or Plateau reading is determined using the advanced algorithm and the same is latched and displayed on the bright 7 segment 2” red Led display. The latched readings are transmitted on two wire RS485 bus for remote display and computer interface. The last 100 readings are stored in the built in memory and can be recalled as and when required.

2) Continuous measurement (CM) – using permanent installation of thermocouple inside the molten metal. The type of thermocouple and temperature measurement range entirely depends on the type of metal such as Brass, Copper, Aluminum, Iron etc… CM allows user to online monitor the temperature on local digital display and on large remote display. In this method No event indications are generated to guide the operator for CM.

SMS Alert: In todays’ era of mobile communication, user is interested in getting all the plant measurement data on his cell phone. Libratherm offers additional facility of generating SMS alert on every spot measurement. Whenever the SM is taken by the operator, the SMS alert can be sent to maximum 5 preselected mobile numbers. The SMS comprises the final temperature reading and the heat number or can be customized as per the user’s requirement. For this facility user have to provide 1 no. of their SIM card subscribed for only SMS facility, from any of the available GSM service provider like Airtel, Idea, Vodafone, BSNL etc…. (or any other as available in that country).

Additional Information:

Remote Audio-Visual Unit for Digital Pyrometer LLC-2010

Remote Audio-Visual Unit for Digital Pyrometer LLC-2010

Approx. Rs 10,000 / Number


Lamp and Hooter Compartment (LLC-2010): For remote audio/visual indications – Libratherm offers this unit having 4 lamps and 1 hooter – which can be driven from the potential free contacts available from LMI-2010.

Additional Information:

Large Display Pyrometer LRU-2010-8Inch

Large Display Pyrometer LRU-2010-8Inch

Approx. Rs 35,000 / Number


Large or Remote Display (LRU-2010): Libratherm offers micro controller based remote display to be used in association with LMI-2010. The final reading available from LMI-2010 can be transmitted on RS485 2 wire bus to this large remote display model LRU-2010, which indicates the latched reading on either 4” or 8” height red 7 segment LED display. With single LMI-2010, maximum 4 nos. of LRU-2010 can be connected in serial multi-drop configuration. LRU-2010 works on 230VAC. LRU-2010 - 4” AND 8” are mainly used for distant viewing and for operator to know the final temperature measurement reading.

Additional Information:

Large Display Pyrometer LRU-2010-4Inch

Large Display Pyrometer LRU-2010-4Inch
  • Large Display Pyrometer LRU-2010-4Inch
  • Large Display Pyrometer LRU-2010-4Inch

Approx. Rs 25,000 / Number


Large Remote Display Temperature Indicator LRU-2010-4Inch

Large or Remote Display (LRU-2010): Libratherm offers micro controller based remote display to be used in association with LMI-2010. The final reading available from LMI-2010 can be transmitted on RS485 2 wire bus to this large remote display model LRU-2010, which indicates the latched reading on either 4” or 8” height red 7 segment LED display. With single LMI-2010, maximum 4 nos. of LRU-2010 can be connected in serial multi-drop configuration. LRU-2010 works on 230VAC. LRU-2010 - 4” AND 8” are mainly used for distant viewing and for operator to know the final temperature measurement reading.

Additional Information:
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Molten Metal Temperature Measuring System ?

    country-ico

    We will contact you soon !

    Kamlesh Panchal

    (Managing Director)

    Libratherm Instruments Private Limited

    Dahisar East, Mumbai, Maharashtra, India

    More Categories

    View All Categories »
    Send SMS
    Contact Us