Send SMS
Contact Us

Humidity And Temperature Sensor and Transmitter

Eco Version Humidity And Temperature Transmitter

Eco Version Humidity And Temperature Transmitter
  • Eco Version Humidity And Temperature Transmitter
  • Eco Version Humidity And Temperature Transmitter
  • Eco Version Humidity And Temperature Transmitter

Approx. Rs 4,500 / Unit


ModelProduct DescriptionSize h x w x d (mm.)
TX-220Wall Mount Temperature Sensor and Transmitter with (8 x 75) mm Pt-100 sensor76 x 70 x 38
TX-220-DM-LDuct Mount Temperature Sensor and Transmitter (Steam Size = 8mm x L mm)
L = 100mm,150mm ,200mm
76 x 70 x 38
HX-220Wall Mount Humidity Sensor and Transmitter76 x 70 x 38
HX-220-DM-LDuct Mount Humidity Sensor and Transmitter (Steam Size = 10 x 20 x L mm)
L = 100mm,150mm,200mm
76 x 70 x 38
HTX-220Wall Mount (Humidity + Temperature) Sensor and Transmitter76 x 70 x 38
HTX-220-DM-LDuct Mount (Humidity + Temperature) Sensor and Transmitter
(Steam Size = 10 x 20 x L mm)
L = 100mm,150mm ,200mm
76 x 70 x 38

Libratherm
offers Economic, rugged and reliable T RH sensor model HTS-220 / HS-220 for measuring Temperature and Humidity in the atmosphere/environment /Chamber. The sensor is easy to mount. For Indication purpose, the external digital display can be used with calibrated scale as given below in the technical specifications.

Applications:

Additional Information:

T-RH Transmitter without Display

T-RH Transmitter without Display

Approx. Rs 5,500 / Unit


Libratherm offers T RH sensor with Transmitter model HYGROTX-3000 and HYGROTX-290 for measuring and transmitting the analogue values proportional to both T and RH Input. The signal generated by Hygroclip is of the order of 1 volt DC and cannot be transmitted over very long distance and if done so the signal is likely to drop over very long cable which will result in the inaccurate measurement of temperature and %RH. The transmitter featured here converts the low level signal to equivalent 4-20mA, which can be transmitted over a long distance without loss of accuracy in the measurement. Dual output of 4-20mA proportional to T and %RH can be used for remote measurement and indication. To suit industrial requirement more advanced transmitters model HTX-3000 are also available with local display. To facilitate interface with PLC or DCS or with any other process controller – digital serial communication on the RS485 bus with MODBUS RTU protocol in slave mode is also provided.

Additional Information:

Temperature Humidity Transmitter without Display

Temperature Humidity Transmitter without Display

Approx. Rs 12,000 / Unit


Libratherm offers T RH sensor with Transmitter model HYGROTX-3000 for measuring and transmitting the analogue values proportional to both T and RH Input.

The signal generated by Hygroclip is of the order of 1 volt DC and cannot be transmitted over very long distance and if done so the signal is likely to drop over very long cable which will result in the inaccurate measurement of temperature and %RH. The transmitter featured here converts the low-level signal to equivalent 4-20mA, which can be transmitted over a long distance without loss of accuracy in the measurement. Dual output of 4-20mA proportional to T and %RH can be used for remote measurement and indication. To suit industrial requirement more advanced transmitters model HTX-3000 are also available with the local display. To facilitate interface with PLC or DCS or with any other process controller – digital serial communication on RS485 bus with MODBUS RTU protocol in slave the mode is also provided.

Additional Information:

Duct Type T- RH Transmitter

Duct Type T- RH Transmitter

Approx. Rs 12,000 / Unit


We are offering Duct Type T-RH Transmitter/T RH Transmitter without Display for Duct Mounting.

Features:


Additional Information:

Eco Version Temperature Humidity Transmitter

Eco Version Temperature Humidity Transmitter

Approx. Rs 4,500 / Unit


Libratherm offers low-cost, rugged and reliable T RH sensor cum Transmitter (model HTX-220) for sensing T Rh in the environment and transmitting the analog values (4-20)mA proportional to both Temperature and Humidity. Normally, the signal generated by T RH sensors are low in strength hence cannot be transmitted over very long distance and if done so the signal is likely to drop over very long cable which will result in the inaccurate measurement of temperature and %RH.

The transmitter featured here converts these low-level signals from Pt-100 and Rh sensor to equivalent 4-20mA, which can be transmitted over a very long distance without loss of accuracy in the measurement. Dual 4-20mA proportional to T and %RH can be used for remote measurement and indication. These transmitter operates on the 24VDC power supply and housed in an ABS plastic enclosure with perforation for sensing. The 24VDC supply and 4-20mA are galvanically isolated from each other and hence prevents any ground line interferences/loading effect while connecting to any external measuring/controlling devices like DCS, PLC, BMS controller or PID controllers.

Additional Information:
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material