Send SMS
Contact Us

Digital Calibrator mV mA RTD Pt-100

Millivolt and Milliamp Calibrator (source/measure) LC-05

Millivolt and Milliamp Calibrator (source/measure) LC-05
  • Millivolt and Milliamp Calibrator (source/measure) LC-05
  • Millivolt and Milliamp Calibrator (source/measure) LC-05

Approx. Rs 12,500 / Number


Millivolt and Milliamp Calibrator (source/measure)
Range: (0.00 to 199.99) mV, (0.0 to 60.0) mV
(0.00 to 30.00) mA.

Description:
Libratherm offers 4 & ½ Digit mV /mA Calibrators model LC-02 and LC-05 which are designed mainly for calibrating temperature and process instruments. Both the models can source and measure the current and voltage signals and hence useful for measuring the sensor outputs as well as for sourcing the signal to the indicator/controller. Model LC-03 is a pt-100 source calibrator for sourcing the resistance corresponding to Pt-100 values with accuracy of 0.01Ohms. 12 fixed ranges are equally divided to cover the temperature range from -100.0oC to + 400.0oC, variable potentiometer is also provided for generating variable resistance values.

Model LC-06V and LC-06C are only voltage and current source meter with 4 and ½ digit display and source range of 0 to 10V or 0 to 60mV or 0 to 25 mA.

Features:
Applications:

Additional Information:

Millivolt and Milliamp DC Source LC-06

Millivolt and Milliamp DC Source LC-06

Approx. Rs 8,500 / Number


Millivolt and Milliamp mV/0-10V/(4-20)mA DC Source

Description:

Model LC-06V and LC-06C are only voltage and current source meter with 4 and ½ digit display and source range of 0 to 10V or 0 to 60mV or 0 to 25 mA.

Libratherm offers 4 & ½ Digit mV /mA Calibrators model LC-02 and LC-05 which are designed mainly for calibrating temperature and process instruments. Both the models can source and measure the current and voltage signals and hence useful for measuring the sensor outputs as well as for sourcing the signal to the indicator/controller. Model LC-03 is a pt-100 source calibrator for sourcing the resistance corresponding to Pt-100 values with accuracy of 0.01Ohms. 12 fixed ranges are equally divided to cover the temperature range from -100.0oC to + 400.0oC, variable potentiometer is also provided for generating variable resistance values.

Features:
Applications:

Additional Information:

Resistor Calibrator for RTD(PT-100) Input LC-03

Resistor Calibrator for RTD(PT-100) Input LC-03

Approx. Rs 5,000 / Number


Resistor Calibrator

Resistor Calibrator for PT-100 Input in the range of
-50 to 400oC with 12 fixed range and one variable.

Description:
Libratherm offers 4 & ½ Digit mV /mA Calibrators model LC-02 and LC-05 which are designed mainly for calibrating temperature and process instruments. Both the models can source and measure the current and voltage signals and hence useful for measuring the sensor outputs as well as for sourcing the signal to the indicator/controller. Model LC-03 is a pt-100 source calibrator for sourcing the resistance corresponding to Pt-100 values with accuracy of 0.01Ohms. 12 fixed ranges are equally divided to cover the temperature range from -100.0oC to + 400.0oC, variable potentiometer is also provided for generating variable resistance values.

Model LC-06V and LC-06C are only voltage and current source meter with 4 and ½ digit display and source range of 0 to 10V or 0 to 60mV or 0 to 25 mA.

Features:
Applications:


Additional Information:

Millivolt Calibrator LC-02

Millivolt Calibrator LC-02

Approx. Rs 5,000 / Number


Digital Calibrators

Millivolt Calibrator (source/measure)
Range: (0.00 to 199.99) mV & (0 to 1999) mV.

Description:
Libratherm offers 4 & ½ Digit mV /mA Calibrators model LC-02 and LC-05 which are designed mainly for calibrating temperature and process instruments. Both the models can source and measure the current and voltage signals and hence useful for measuring the sensor outputs as well as for sourcing the signal to the indicator/controller. Model LC-03 is a pt-100 source calibrator for sourcing the resistance corresponding to Pt-100 values with accuracy of 0.01Ohms. 12 fixed ranges are equally divided to cover the temperature range from -100.0oC to + 400.0oC, variable potentiometer is also provided for generating variable resistance values.

Model LC-06V and LC-06C are only voltage and current source meter with 4 and ½ digit display and source range of 0 to 10V or 0 to 60mV or 0 to 25 mA.

Features:

Applications:
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Digital Calibrator mV mA RTD Pt-100 ?

    country-ico

    We will contact you soon !

    Kamlesh Panchal

    (Managing Director)

    Libratherm Instruments Private Limited

    Dahisar East, Mumbai, Maharashtra, India

    More Categories

    View All Categories »
    Send SMS